Utility-Scale Solar Infrastructure / Photovoltaic EPC
Utility-scale solar torque-tube bracket: from 3 welded plates to one cold-formed profile
- Unit cost
- −34%
- Secondary reaming eliminated
- 100%
Capabilities & Processes
Coating specification decides service life. Argonis specifies and verifies hot-dip galvanizing, powder coating and duplex systems against the corrosivity category of the installation site.
| Parameter | Value |
|---|---|
| Hot-dip galvanizing kettle | 13.5 × 1.8 × 3.2 m |
| Spin galvanizing | Fasteners and small parts |
| Powder coating line | Zinc-phosphate pre-treatment, thermoset powders |
| Duplex systems | HDG + powder to EN 15773 / EN 13438 |
| Tolerance class | EN ISO 1461 minimum thickness, steel > 6 mm: 70 µm local / 85 µm mean; 3–6 mm: 55 / 70 µm. Powder 60–120 µm. |
Utility-Scale Solar Infrastructure / Photovoltaic EPC
Surface Finishing
For steel thicker than 6 mm, EN ISO 1461 requires a 70 µm local minimum and 85 µm mean minimum. Argonis logs magnetic gauge readings per batch.
Tell us about scope, timeline and site. Our project team responds within one business day.